EDUTECH LAHORE

FM-118 | Centrifughal Pump Charateristics

  • Determining the relationship between head, discharge, speed, power, and efficiency for a centrifugal pump at various speeds
  • Determining the head/flow rate characteristics of two similar pumps operating in either parallel or series configuration at the same speed (only single pump supplied)
  • Compatible with FM-430 Hydraulic Bench
  • LxWxH 360x160x325mm
Description
Technical Specification
Media
This accessory comprises a variable speed pump assembly and independent discharge manifold interconnected by flexible tubing with quick release connectors. This pump is intended to be used in conjunction with the basic Hydraulics Bench. The pump speed is varied by an inverter drive. The motor speed, output voltage and motor current can be monitored on the inverter display. A compound pressure gauge is mounted on the pump inlet and a pressure gauge is mounted on the pump outlet. An independent discharge manifold incorporates a pressure gauge and flow control valve prior to a discharge pipe with diffuser.
Standards
  • Machinery Directive 2006/42/EC,
  • Low Voltage Directive 2006/95/EC,
  • Electromagnetic Compatibility Directive 2004/108/EC.
  • Pump: Centrifugal type
  • Max head : 21 m Approx
  • Max flow: 1.35 L/s
  • Motor rating: 360 W Approx.
  • Speed controller: Frequency inverter
  • Speed range: 0-1500 rpm
  • Pressure gauge range: 0-60m
  • Compound gauge range: –10 to +32m