EDUTECH LAHORE

FM-407 | Free and Forced Vortices

  • To produce and measure the characteristics of free and forced vortices using a hydraulics bench
  • Compatible with FM-430 Hydraulic bench
  • LxWxH: 600 x 500 x 460 mm
Description
Technical Specification
Media
The apparatus comprises a clear acrylic cylinder on a plinth designed to produce and measure free and forced vortices. The free vortex is generated by water discharging through an interchangeable orifice in the base of the cylinder, and the resulting profile is measured using a combined calliper and depth scale. The forced vortex is induced by a paddle in the base of the cylinder, which is rotated by jets of water. The profile of the forced vortex is determined using a series of depth gauges. Velocity at any point in the free or forced vortices may be measured using the appropriate pitot tube supplied.
Standards
  • Machinery Directive 2006/42/EC,
  • Tank diameter: 245mm
  • Height to overflow point: 180mm
  • Orifice diameters: 8, 12, 16 and 24mm
Forced vortex measuring probes
  • Distance from centre: 0, 30, 50, 70, 90 and 110mm
  • Pitot tubes having measuring point (nose) at: 15, 25 and 30mm radius
  • Inlet tubes: 9 and 12.5mm diameter